Awlfair SF is a new-generation Awlgrip product in which the fairing filler is applied by pressurised airless spray instead of a trowel. Spray application eliminates trapped air and gives fast, even-thickness filling on large surfaces.
With SF, coats are applied wet-on-wet, up to two coats per day. No sanding is needed between coats. This noticeably shortens the overall job time on large projects.
What does Awlfair SF do and where does it sit in the paint system?#
SF takes the same place in the system as Awlfair LW: it fills, levels and smooths surface defects caused by gouges, low spots, dents and weld seams. A high-build primer goes over it.
Which surfaces and where is it used?#
- Large yacht and superyacht hull fairing
- Large surfaces where trapped air is critical
- High-volume, fast schedules
Surface preparation: the stage that decides the outcome#
SF is applied over a suitable Awlgrip primer. Airless pump, hose and gun settings must be prepared according to the product data sheet and the representative's recommendation.
Application: step by step#
SF's application logic differs from trowelled fillers. The material is sprayed at an even thickness with airless spray and coats are applied wet-on-wet. Up to two coats can be applied per day and no sanding is needed between coats. After cure it is sanded as a profiling filler by board and machine (application guide: P40–P80).
- Equipment
Airless pump and data sheet settings.
- 1st coat
Spray at an even thickness.
- 2nd coat (same day)
Wet-on-wet, no sanding.
- Cure
Time per data sheet.
- Sanding and sealing
P40–P80; then high-build primer.
Application conditions: temperature, humidity and dew point#
The general conditions of the Awlfair family apply: no application below 13 °C or above 40 °C. Check the SF data sheet for exact values.
Tips from the professionals#
- Monitor layers with a wet film comb.
- Work in a wind-free, controlled environment; airless overspray spreads over a wide area.
- Keep masking generous.
Common mistakes#
- Wet-on-wet, 2 coats per day
- Wet film measurement
- Board sanding after cure
- Unnecessary sanding between coats
- Equipment set up without the data sheet
- Spraying in windy conditions
Health and safety#
Frequently asked questions#
How is Awlfair SF applied?
By pressurised airless spray; coats wet-on-wet, up to two coats per day.
Is sanding needed between SF coats?
According to the manufacturer's page, no.
_Source: Awlgrip / AkzoNobel, Awlfair SF product page (awlgrip.com/europe); Awlgrip Application Guide (22nd edition). The values on this page are compiled from documents published by the manufacturer and may change as the product evolves. Always check the product label, the current technical data sheet (TDS) and the safety data sheet (SDS) before application._