Max Cor CF is a high-solids, two-component, chromate-free anti-corrosive epoxy primer developed for aluminium and steel surfaces. Its "CF" (Controlled Fusion) technology means no sanding is required before the next coat, as long as you stay within the window.
Max Cor CF's most critical feature is its time window. Recoated within the window, it gives excellent adhesion without sanding. If the window is missed, the data sheet's explicit warning applies: the product must be completely removed and reapplied.
What does Awlgrip Max Cor CF do and where does it sit in the paint system?#
Max Cor CF is the first coat on the metal. Hullgard Extra or High Build goes over it. On projects with long waits, Hullgard Extra applied over Max Cor CF on time extends the recoat window to 6 months.
Which surfaces and where is it used?#
- Aluminium hulls and superstructures (above the waterline)
- Steel boats and hardware (above the waterline)
- First coat on metal surfaces that need fairing (Hullgard Extra over it)
Surface preparation: the stage that decides the outcome#
Steel is blasted to SSPC-SP10 (Sa 2½) with a 50–75 µm profile or ground with a 16–36-grit disc. Aluminium is blasted or ground to a 100% clean, silver-bright surface. The surface must be dry, free of dirt and grease, and wiped with Awlgrip wipe solvent (T0340 in Europe).
Mix ratio, induction and pot life#
Max Cor CF is mixed by volume 2 parts R4330 + 1 part R3330. First the base itself is made homogeneous. The product is not reduced. Pot life at 25 °C is only 2 hours, so the mix is prepared in small batches to match the application rate.
| Value | Data sheet value |
|---|---|
| Mix | 2 : 1 (R4330 : R3330) |
| Induction | None |
| Reducer | Not used |
| Pot life | 2 h (25 °C, 50% humidity) |
Application: step by step#
Max Cor CF is applied by spray only, as a single, smooth, wet coat. Aim for 20–34 µm wet, 15–25 µm dry film per coat; this upper limit must not be exceeded. Because the film is thin, the substrate may show through; this is normal.
- Preparation
Profile, cleaning, T0340 wipe.
- Mix
2:1, no reduction; small batches.
- Single wet coat
20–34 µm wet, 15–25 µm dry.
- Waiting time
At least 17 hours at 15–25 °C.
- Topcoat
Hullgard Extra or High Build before 72 hours are up.
| Conventional (compliant) | Value |
|---|---|
| Air cap / tip | 110 / 1,4 |
| Atomisation | 2.0–2.7 bar |
| Pressure pot | 0.8 bar |
| Airless | 0,013" / 60° |
Drying and recoat times#
Max Cor CF's recoat window is the same for Hullgard Extra and High Build.
| Temperature | Minimum | Maximum |
|---|---|---|
| 15 °C | 17 h | 72 h |
| 25 °C | 17 h | 72 h |
| 35 °C | 7 h | 72 h |
Application conditions: temperature, humidity and dew point#
Max Cor CF's lower limit is higher than other primers': it is not applied to surfaces below 15 °C or above 40 °C, and curing must not be attempted below 15 °C.
Tips from the professionals#
- Check with a wet film comb that you do not go above 34 µm.
- Pot life is 2 hours; on large surfaces work with two people and in batches.
- If the window is at risk, apply Hullgard Extra at the first opportunity.
Common mistakes#
- A single, thin, wet coat
- Hullgard Extra within 17–72 hours
- Used without reduction
- Heavy coat, maximum DFT exceeded
- Window missed but recoated anyway
- Application below 15 °C
Health and safety#
Frequently asked questions#
What is the mix ratio of Max Cor CF?
By volume 2 parts R4330 + 1 part R3330; not reduced.
When can Max Cor CF be recoated?
At 15–25 °C minimum 17, maximum 72 hours; at 35 °C minimum 7 hours.
What happens if 72 hours pass?
According to the data sheet, the coating must be completely removed and reapplied.
_Source: Awlgrip / AkzoNobel, Max Cor CF Primer (R4330/R3330) technical data sheet (Rev. 11); Awlgrip Application Guide (22nd edition). The values on this page are compiled from documents published by the manufacturer and may change as the product evolves. Always check the product label, the current technical data sheet (TDS) and the safety data sheet (SDS) before application._