In Awlgrip systems a reducer is chosen not just to thin the paint but to match the evaporation rate to the conditions. The wrong reducer leads to lap marks, orange peel, sags or solvent entrapment.
The application guide sets a clear rule: no reducer, additive or converter not specifically recommended by Awlgrip may be used. Doing so may void the warranty.
What do Awlgrip reducers do and where do they sit in the paint system?#
A fast reducer prevents the film from sagging in the cold; a slow reducer keeps the wet edge open in the heat. The brushing reducer T0031 evaporates slowly so brush marks can flow out.
Which surfaces and where is it used?#
- T0001 (16–24 °C), T0002 (13–21 °C), T0003 (21–32 °C), T0005 (32–41 °C): urethane topcoat spray
- T0006: epoxy primer spray (545, High Build, Awlquik, Hullgard Extra)
- T0031: brush/roller (Awlgrip Topcoat H3002, 545, Awlquik)
- T0073: Ultra Build
- T0016: Awlspar brushing only
Surface preparation: the stage that decides the outcome#
The reducer is chosen by ambient and surface temperature, airflow and panel size. On large panels and in windy conditions, a reducer one step slower keeps the wet edge.
Application: step by step#
The reduction ratio is always kept within the range in the product data sheet. For example, Awlcraft 2000 is reduced 0–33%, 545 spray 0–25%, Hullgard Extra max. 15%. Max Cor CF and Wash Primer CF are not reduced at all.
- Identify the product
Reducer code in the data sheet.
- Measure the temperature
Surface and ambient.
- Choose the reducer
Speed by range.
- Apply the ratio
Within the data sheet range.
- Trial
Spray test on a small panel.
| Product | Reducer | Ratio |
|---|---|---|
| Awlgrip Topcoat (spray) | T0001/2/3/5 | %0–25 |
| Awlcraft 2000 | T0001/2/3/5 | %0–33 |
| 545 (spray / brush) | T0006 / T0031 | %0–25 / %5–10 |
| High Build | T0006 | %10–20 |
| Hullgard Extra | T0006 | ≤ 5% (never > 15%) |
| Ultra Build | T0073 | %5–25 |
| Max Cor CF, Wash Primer CF | — | Not reduced |
Application conditions: temperature, humidity and dew point#
The temperature ranges in the application guide are a starting point; wind, sun and panel size can shift the choice by one step.
Tips from the professionals#
- Clean equipment with the cleaner given in the data sheet (e.g. T0002).
- Close reducer cans tightly; a reducer that has picked up moisture spoils polyurethane.
Common mistakes#
- Reducer from the data sheet
- Speed by temperature
- Ratio within the data sheet range
- General-purpose thinner
- T0016 in epoxy
- Reducing Max Cor CF
Health and safety#
Frequently asked questions#
What is the difference between T0001 and T0003?
T0001 is the fast (16–24 °C) and T0003 the standard (21–32 °C) topcoat spray reducer.
Which reducer is used in epoxy primers?
T0006 for spray; T0031 for brush/roller.
Where is T0016 used?
Only in Awlspar varnish.
_Source: Awlgrip Application Guide (22nd edition); respective product technical data sheets. The values on this page are compiled from documents published by the manufacturer and may change as the product evolves. Always check the product label, the current technical data sheet (TDS) and the safety data sheet (SDS) before application._