Interprotect 2000E is a two-pack epoxy primer used for corrosion and blister protection on steel, aluminium and GRP surfaces.
After mixing, Interprotect 2000E is left for 20 minutes of induction and then thinned. Total thickness is approximately 254 µm.
What does Interprotect 2000E do and where does it sit in the paint system?#
Interprotect 2000E forms a protective epoxy barrier on the surface.
Which surfaces and where is it used?#
- Steel and aluminium primer
- GRP osmosis protection
- Primer before antifouling
Surface preparation: the stage that decides the outcome#
The surface must be clean, dry and grease-free. It is prepared with suitable sandpaper.
Mix ratio, induction and pot life#
Base and hardener are mixed at 3 : 1 by volume. 20 minutes induction is waited; then thinner is added.
Thinner 2316N or 2333N (brush); YTA910 for spray. On steel and aluminium the first coat is 15–20% thinned, spray 10–15%.
| Application | Reduction |
|---|---|
| Brush / first coat (steel, aluminium) | 15–20% (2316N / 2333N) |
| Spray | 10–15% (2316N or YTA910) |
Application: step by step#
Applied by roller in 4–5 coats (66 µm dry per coat) or by spray in 2–3 coats (137 µm dry per coat). Total thickness is approximately 254 µm. One coat is applied before filling.
- Mix
3 : 1 by volume.
- Induction
Wait 20 min.
- Thin
According to the table.
- Apply
Roller or spray.
- Total
Approximately 254 µm.
| Application | Coat | Dry film / coat | Wet film / coat |
|---|---|---|---|
| Roller | 4–5 | 66 µm | ~145 µm (5.6 mil) |
| Spray | 2–3 | 137 µm | ~305 µm (12 mil) |
Drying and recoat times#
Interprotect 2000E is touch-dry in 2 hours at 23 °C and can be immersed in 12 hours. Recoat window is 3 hours to 6 months.
| Stage (23 °C) | Time |
|---|---|
| Touch dry | 2 h |
| Immersion | 12 h |
| Recoat (min) | 3 h |
| Recoat (max) | 6 months |
Application conditions: temperature, humidity and dew point#
Product and ambient 5–35 °C; not applied above 85% relative humidity.
Tips from the professionals#
- Wait 20 min induction.
- Adjust coat thickness according to the technical data sheet.
- Check relative humidity.
- Follow the recoat window.
Common mistakes#
- Correct induction
- Total 254 µm
- Adhere to recoat time
- Humidity control
- Application over single-pack paint
- Permanent immersion
- Application in humid environment
- Skipping induction
Health and safety#
Frequently asked questions#
Interprotect 2000E mix?
3 : 1 by volume.
Interprotect 2000E induction?
20 min.
Interprotect 2000E total thickness?
Approximately 254 µm.
Interprotect 2000E pot life?
3 h at 23 °C.
_Source: International Yacht Paint (AkzoNobel) product technical data sheet (TDS) and product page (Interprotect 2000E (lewismarine) data sheet). The values on this page are compiled from the manufacturer's published documents and may change as the product develops. Before application, always check the product label, the current technical data sheet (TDS) and the safety data sheet (SDS)._