SeajetOther

Seajet Pellerclean: how is it applied?

Seajet Pellerclean is a system of a yellow epoxy primer and a silicone-based, biocide-free transparent foul-release clear coat for propellers and metal parts. Mixing, thinning, film thickness, drying times and application conditions according to the manufacturer data sheet.

  • 3 min read
  • Updated:

Seajet Pellerclean is a system of a yellow epoxy primer and a silicone-based, biocide-free transparent foul-release clear coat for propellers and metal parts.

Mixing, thinning, film thickness, drying times and application conditions are summarised from the manufacturer data sheet.

Seajet Pellerclean: technical summary and drying times
Key values for Seajet Pellerclean (manufacturer data sheet)

What is Seajet Pellerclean for and where is it used?#

  • Protection of propellers and outdrives
  • Biocide-free foul-release protection

Application sequence#

  • Wash and degrease; abrade with P180 for repairs.
  • Apply 1 thin coat of primer.
  • Clear coat: 2–3 coats on first application; 2 coats for repair.
  • Maintenance: light pressure wash or hose and sponge.

Mixing and thinning#

Base and hardener are mixed at 79 : 21 (primer) by volume; the hardener is added while stirring and mixed thoroughly.

Thinner: SEAJET THINNER E (astar) / A (clear coat), ratio 0–5 % (by volume).

Application method and film thickness#

  • Wet film per coat: Primer 140 µm; clear coat 91 µm
  • Dry film per coat: Primer 70 µm; clear coat 75 µm
  • Theoretical coverage: 7.1 m²/l (primer), 10.9 m²/l (clear coat)
  • Volume solids: 50 ±2 % (primer), 82 ±2 % (clear coat)
  • Mask surrounding surfaces against silicone contamination and discard brushes and rollers.

Drying and recoat times (20 °C)#

  • Surface dry: 30 min
  • Hard dry: 3 h

Drying times increase with film thickness; make sure the film is fully dry before recoating.

Application conditions#

  • Minimum temperature: 0 °C
  • Maximum relative humidity: 85 %
  • Do not apply in rain, fog, condensation or direct sun; make sure the surface is dry.

Common mistakes#

  • Changing the application order
  • Applying without degreasing the surface
  • Ignoring the recoat intervals
  • Not masking surrounding areas against silicone contamination

Health and safety#

The product is flammable; keep it away from sparks and open flames and do not smoke in the work area. Ventilate, and avoid skin contact and inhaling spray mist. In case of eye contact, rinse with plenty of water and seek medical advice. Do not pour waste into drains. Flash point: 26 °C (primer), 34 °C (clear coat). VOC (theoretical): 363 g/l (primer), 130 g/l (clear coat).

Frequently asked questions#

How long does Seajet Pellerclean take to dry at 20 °C?

Surface dry: 30 min; Hard dry: 3 h.

How is Seajet Pellerclean thinned?

Value stated in the data sheet: SEAJET THINNER E (primer) / A (clear coat): 0–5 %.

_Source: Chugoku Paints B.V. Seajet technical data sheet (210EE (astar) + 605FR (clear coat)). The values on this page are compiled from the manufacturer’s published documents and may change as the product develops. Before application, always check the product label, the current technical data sheet (TDS) and the safety data sheet (SDS)._

On-site survey

Right product, right application

We inspect your boat on site and recommend the suitable system in writing.